loading page

TUBE SIDE HEAT TRANSFER
  • Md Tarif Raihan
Md Tarif Raihan

Corresponding Author:[email protected]

Author Profile

Abstract

The current research was carried out to investigate conventional heat transfer enhancement inside the tube by using twisted stainless-steel angle insert. Main objectives were to find the percentage of increment of heat transfer enhancement using twisted stainless-steel insert and to find the relation between Reynolds number and Nusselt number. A 940mm long copper tube of 26.6 mm internal diameter and 30 mm outer diameter, of which length of 762 mm has been used as the test section. A constant heat flux condition has been maintained by wrapping Nichrome wire around the test section and fiber glass insulation over the wire. K-type thermocouples and rotameter were used to measure temperature and rate of flow. With insert, heat transfer rate has been increased up to 140 percent. This technique does not rely on external power or activation. This experiment has shown simultaneous effects on Reynolds number and Nusselt number too.