Abstract
The position sensorless Permanent Magnet Synchronous Motor (PMSM) is
widely applied in the field of high reliability, and its driver, the
inverter is controlled by closed loop feedback with the three-phase
current. For medium and high power PMSM, both safety isolation and
detection accuracy of measuring current are extremely significant. This
paper presents a method of using Current Transformer (CT) with center
taps to measure the high-frequency switch current and of an algorithm to
reconstruct the low-frequency three-phase current. The measurement unit
and reconfiguration algorithm are then applied to the motor starting
stage controlled by the DSP controller TMS320F28335. Lastly, by
comparing the waveform of the reconstructed current and one of the
inverter phase current, the experimental results show that the proposed
reconstruction method is effective.