Aortic valve regurgitation in patients undergoing LVAD implantation is a significant complication which occurs in up to 10% of patients in the INTERMACS database. Patients who have aortic valve regurgitation at the time of implant have been handled by several methods, including aortic valve leaflets approximation, to aortic valve replacement or even valve closure. We report a case where we used HAART Ring to repair a regurgitant aortic valve during LAVD implant for destination therapy.