loading page

Photoplethysmography for non-invasive diagnosis of cold urticaria
  • +10
  • Daria Fomina,
  • Sofia Serdotetskova,
  • Alexander Machikhin,
  • Mikhail Volkov,
  • Anastasia Guryleva,
  • Mojca Bizjak,
  • Valeriya Bukova,
  • Marina S. Lebedkina,
  • Gerelma Andrenova,
  • Olga Mukhina,
  • Mukatova Irina,
  • Inna Danilycheva,
  • Marcus Maurer
Daria Fomina
GBUZ Gorodskaa kliniceskaa bo'lnica No 52 Departamenta zdravoohranenia goroda Moskvy

Corresponding Author:[email protected]

Author Profile
Sofia Serdotetskova
GBUZ Gorodskaa kliniceskaa bo'lnica No 52 Departamenta zdravoohranenia goroda Moskvy
Author Profile
Alexander Machikhin
FGBUN Naucno-tehnologiceskij centr unikal'nogo priborostroenia Rossijskoj akademii nauk
Author Profile
Mikhail Volkov
FGBUN Naucno-tehnologiceskij centr unikal'nogo priborostroenia Rossijskoj akademii nauk
Author Profile
Anastasia Guryleva
FGBUN Naucno-tehnologiceskij centr unikal'nogo priborostroenia Rossijskoj akademii nauk
Author Profile
Mojca Bizjak
Klinika Golnik
Author Profile
Valeriya Bukova
FGBUN Naucno-tehnologiceskij centr unikal'nogo priborostroenia Rossijskoj akademii nauk
Author Profile
Marina S. Lebedkina
GBUZ Gorodskaa kliniceskaa bo'lnica No 52 Departamenta zdravoohranenia goroda Moskvy
Author Profile
Gerelma Andrenova
GBUZ Gorodskaa kliniceskaa bo'lnica No 52 Departamenta zdravoohranenia goroda Moskvy
Author Profile
Olga Mukhina
GBUZ Gorodskaa kliniceskaa bo'lnica No 52 Departamenta zdravoohranenia goroda Moskvy
Author Profile
Mukatova Irina
Astana Medical University
Author Profile
Inna Danilycheva
NRC Institute of Immunology FMBA of Russia
Author Profile
Marcus Maurer
Charite Universitatsmedizin Berlin
Author Profile

Abstract

Background: Cold urticaria (ColdU) is a common type of chronic inducible urticaria. Patients with typical ColdU develop wheals in response to standard cold stimulation tests (CSTs), an ice cube (ICT) or TempTest ®. As of now, the evaluation of CST response is visual and subjective. Validated, robust, and objective test readouts lacking today are needed. Methods: We subjected 63 patients (39 with typical ColdU and 24 with atypical ColdU) and 15 healthy controls (HCs) to TempTest ® CSTs and critical temperature threshold assessments. Blood microcirculation photoplethysmography (PPG) measurements were performed 5 min before and 10 min after the ICT on the volar forearm. Results: PPG amplitudes reflected normal baseline skin blood perfusion in patients with typical or atypical ColdU. Ice cube CSTs induced a marked increase in blood perfusion and PPG amplitudes in typical but not atypical ColdU, with distinct pre-post CST changes in PPG amplitudes in the former. The ratio of post-provocation and baseline PPG amplitudes ( R PPG) in typical ColdU patients exceeded that in atypical ColdU patients and HCs more than 3-fold. Almost all typical ColdU patients (98%), but only 13% of atypical ColdU patients and 7% of HCs had R PPG >3. PPG results matched those of CSTs in 94% of all tested individuals. Conclusion: Photoplethysmographic assessments of CST responses appear accurate and provide objective readouts. PPG may be of use in diagnosing ColdU, distinguishing typical and atypical ColdU, and more precise threshold testing.