loading page

Modified Ablation Index: A Novel Determinant of Successful First-Pass Left Atrial Posterior Wall Isolation
  • +7
  • Satoshi Hayashida,
  • Koichi Nagashima,
  • Sayaka Kurokawa,
  • Masaru Arai,
  • Ryuta Watanabe,
  • Yuji Wakamatsu,
  • Naoto Otsuka,
  • Seina Yagyu,
  • Kazuki Iso,
  • Yasuo Okumura
Satoshi Hayashida
Nihon University School of Medicine

Corresponding Author:[email protected]

Author Profile
Koichi Nagashima
Nihon University School of Medicine
Author Profile
Sayaka Kurokawa
Nihon University School of Medicine
Author Profile
Masaru Arai
Nihon University School of Medicine
Author Profile
Ryuta Watanabe
Nihon University School of Medicine
Author Profile
Yuji Wakamatsu
Nihon University School of Medicine
Author Profile
Naoto Otsuka
Nihon University School of Medicine
Author Profile
Seina Yagyu
Nihon University School of Medicine
Author Profile
Kazuki Iso
Kawaguchi Municipal Medical Center
Author Profile
Yasuo Okumura
Nihon University School of Medicine
Author Profile

Abstract

Introduction Although left atrial posterior wall isolation (LAPWI) in addition to pulmonary vein isolation is a well-accepted option for persistent atrial fibrillation (AF), complete isolation can be challenging. To evaluate performance of a modified ablation index (AI) (AI/bipolar voltage along the ablation line) for predicting durable LAPWI. Methods The study involved 55 consecutive patients, aged 65 ± 11 years, who underwent electroanatomic mapping-guided LAPWI for AF. Association between gaps (first-pass LAPWI failure and/or acute LAPW reconnections), voltage amplitude along the roof and floor lines, and thickness of the LAPW was investigated. Results Gaps occurred in 22 patients (40%) and in 26 (8%) of the 330 line segments assessed—11 in the center roof line segment, 6 in the center floor line segment, 4 in the right roof line segment, 4 in the right floor line segment, and 1 in the left floor line segment. Gaps were associated with relatively high bipolar voltage (3.38 ± 1.83 vs. 1.70 ± 1.12 mV, P < 0.0001) and a thick LA wall (2.52 ± 1.15 vs. 1.42 ± 0.44 mm, P < 0.0001). A modified AI ≤ 199 AU/mV, bipolar voltage ≥ 2.64 mV, wall thickness ≥ 2.04 mm, and roof ablation line ≥ 43.4 mm well predicted gaps (AUCs: 0.783, 0.787, 0.858, and 0.752, respectively). Conclusions High voltage zones, a thick LAPW, and a long roof ablation line appear to be determinants of gaps, and a modified AI ≥ 199 AU/mV along the ablation lines appears to predict acute durable LAPWI.
May 2022Published in Heart and Vessels volume 37 issue 5 on pages 802-811. 10.1007/s00380-021-01971-3