The muscle bundle approach for catheter ablation of the cavotricuspid
isthmus: a propensity score-matched cohort study
Abstract
Introduction Pathological studies have demonstrated that the
cavotricuspid isthmus (CTI) is often composed of discrete muscle bundles
that correlate with high-voltage local electrograms. The main objective
was to demonstrate that ablation of high-voltage muscle bundles in the
cavotricuspid isthmus (CTI), identified using an intracardiac mapping
system, reduces radiofrequency (RF) time compared to the conventional
technique. Methods A retrospective analysis of patients who had
undergone CTI ablation guided by a mapping system. The patients were
divided into two groups according to operator experience and selected by
propensity score-matched analysis: group A, RF delivery in high-voltage
bundles and group B, RF delivery producing a contiguous line of ablation
lesions along the entire CTI length. Results Thirty-eight patients
[92.1% male, 64 yrs (57-70)] were selected, 19 in each group. There
were no differences in baseline characteristics or clinical results:
success (A: 94.7% vs B: 94.7%), complications (A: 5.3% vs B: 0%) and
recurrence (A: 10.5% vs B: 5.3%). In the procedures in group A, fewer
RF applications were delivered [14 (9–19) vs 20 (2–25);
P < 0.05] with greater contact force [14.5 g (13–16.2) vs
12 g (9-14); P < 0.01] and greater lesion size index (LSI)
[5.3 (4.9–6) vs 4.5 (4.1–4.7); P < 0.001]. The RF time
was less (P < 0.001) in group A [310 s (211–479) vs 577 s
(312–858)]. Conclusions Application of RF in CTI muscle bundles
reduces RF time, compared to conventional linear ablation, with similar
clinical results.