Improved real-time recordings using the fourth generation cryoballoon technology -- detection of dual fascicle electrograms
  • +7
  • Vedran Velagić,
  • Giacomo Mugnai,
  • Vedran Pasara,
  • Ivan Prepolec,
  • Mislav Puljevic,
  • Borka Pezo-Nikolic,
  • Davor Puljevic,
  • Jure Samardzic,
  • Maja Cikes,
  • Davor Milicic
Vedran Velagić
University of Zagreb School of Medicine, University Hospital Centre Zagreb, Zagreb, Croatia

Corresponding Author:[email protected]

Author Profile
Giacomo Mugnai
Division of Cardiology, West Vicenza General Hospitals, Vicenza, Italy
Author Profile
Vedran Pasara
University of Zagreb School of Medicine, University Hospital Centre Zagreb, Zagreb, Croatia
Author Profile
Ivan Prepolec
University of Zagreb School of Medicine, University Hospital Centre Zagreb, Zagreb, Croatia
Author Profile
Mislav Puljevic
University of Zagreb School of Medicine, University Hospital Centre Zagreb, Zagreb, Croatia
Author Profile
Borka Pezo-Nikolic
University of Zagreb School of Medicine, University Hospital Centre Zagreb, Zagreb, Croatia
Author Profile
Davor Puljevic
University of Zagreb School of Medicine, University Hospital Centre Zagreb, Zagreb, Croatia
Author Profile
Jure Samardzic
University of Zagreb School of Medicine, University Hospital Centre Zagreb, Zagreb, Croatia
Author Profile
Maja Cikes
University of Zagreb School of Medicine, University Hospital Centre Zagreb, Zagreb, Croatia
Author Profile
Davor Milicic
University of Zagreb School of Medicine, University Hospital Centre Zagreb, Zagreb, Croatia
Author Profile

Abstract

Introduction: We aimed to analyze the rate of visualization of real-time (RT) recordings and dual fascicle electrograms in our first series of patients treated with the fourth generation cryoballoon (CB) device. Methods: All consecutive patients who underwent CB ablation using the fourth generation technology were included in the analysis. In all procedures we used a 28 mm CB placed via a single transseptal puncture guided by intracardiac ultrasound. A 20 mm octapolar intraluminal circular catheter was used for intracranial recordings. A single 180 seconds freeze strategy was employed. Results: A total of 123 patients (72.9% male, mean age 60.1±10.9 years) were enrolled in the study. RT recordings were detected in 445 (86.2%) pulmonary veins (PVs). Specifically, RT recordings were visualized in 115 left superior PVs (89.2%), 107 left inferior PVs (82.9%), 118 right superior PVs (91.4%) and 105 right inferior PVs (81.3%). Furthermore, in 23 of 516 PVs (4.4%), two fascicle electrograms were detected. Dual fascicles were most commonly observed in left superior PV (6.2%). In both inferior PVs dual fascicles were observed in 4.6% while this phenomenon was least frequent in right superior PV (2.3%). Conclusion: By using the fourth-generation CB we report a specific pattern of isolation represented by a sequential isolation of two apparently distinct PV fascicles during a single CB freeze delivery. This phenomenon occurred in 4.4% of PV ablations. Of note, the rate of visualization of RT isolation with this novel CB was very high and could be documented in 86.2% of PVs.